825 CUTTING AND CAPPING MAST ARMS AND POLES

From MDOT Policy Manual
Jump to: navigation, search
825.01 DESCRIPTION.
Cut, clean, galvanize, and cap mast arms, mast arm poles, pedestal poles, and strain poles.
825.02 MATERIALS.
Cold Galvanizing Compound       A 780
825.03 CONSTRUCTION.
Galvanized parts that have been cut or chipped to bare metal shall be repaired per A 780.
Saw cut the pole or mast arm to the required length. Clean the area inside and outside with a wire brush. Spray cold galvanizing compound on the affected area. Place an end cap of matching size.
825.04 MEASUREMENT AND PAYMENT.
Cutting and Capping of Mast Arms and Poles will be measured and paid for at the Contract unit price per each. The payment will be full compensation for all material, labor, equipment, tools, and incidentals necessary to complete the work.